公司研制的8串鋰電動力電池保護板,本產品嚴格滿足ROHS規范等。This specification applies to the 8 serial-cells lithium manganate battery protection board which strictly conforms to the ROHS standard.
二、應用范圍Application
錳酸鋰、三元材料、鈷酸鋰、磷酸鐵鋰等鋰離子、鋰聚合物等可充電電池包等。
三、電氣參數Electrical Characteristic (Ta = 25 ℃.)
Details Min. Typ. Max Error Unit
Battery Gas電池類型 3.2V鋰電池
Battery Link電池組組合方式 8串
Loop capability回路性能
Input Charging Voltage 充電電壓 29.6 ±1% V
Input Charging Current 充電電流 5 7 A
Output Discharging Voltage放電電壓 25.6 V
Output Discharging Current放電電流 10 15 A
Continuous Output Discharging Current(可持續工作電流) ≤15 A
Ambient Condition Operating Temperature工作溫度 -20 25 60 ℃
Humidity (No Water-Drop)工作濕度 0% 90% RH
Storage Temperature 存儲溫度 -40 85 ℃
Humidity (No Water-Drop)存儲濕度 0% 90% RH
Protection Parameters (for Individual Cell).
Over-Charge Voltage Protection (OVP) 過充保護電壓 3.90 ±25mV V
Over-Charge Voltage Protection Release (OVPR)過充恢復電壓 3.80 ±50mV V
Over-Discharge Voltage Protection (UVP)過放保護電壓 2.00 ±50mV V
Over-Discharge Voltage Protection Release (UVPR)過放恢復電壓 2.50 ±50mV V
Over-Current Discharge Protection (OCDP)放電過流保護 30 ±7 A
Over-Current Protection Delay Time (OCPDT)過流保護延時 12 ±5 mS
Over-Current Discharge Protection Release放電過流保護恢復方式 斷開負載
Short circuit current protection短路保護 有短路保護
Short circuit current protection delay time短路保護延時 612 ±100 uS
Short circuit protection Release短路保護恢復時間 斷開負載
Discharging Temperature放電保護溫度 75 ±5℃ ℃
Discharging Temperature Protection Release放電保護恢復溫度 60 ±5℃ ℃
charging Temperature充電保護溫度 75 ±5℃ ℃
charging Temperature Protection Release充電保護恢復溫度 60 ±5℃ ℃ |
 |
|